OT furnace fan limit switch question??
[ Expand ] [ View Replies ] [ Add a Reply ] [ Return to Forum ]
Posted by PhilcaseinWPa on October 24, 2006 at 11:41:02 from (146.186.55.48):
Well it's getting cold so like everything else I do I decided at the last minute to check to see if the furnace would run (natural gas, forced hot air). I cleaned out all the cobwebs and dust, set the thermostat and turned on the furnace. Started up just fine but the blower fan never came on and the furnace eventually stopped. Then tried to start again and would run a few seconds and shut off over and over. I found the fan limit switch for the blower and by turning the dial a little I was able to get the blower to kick on and run. Got the house a little warmer. But when the furnace kicked on again the blower wouldn't start unless I turned the limit dial by hand. Finally I got my glasses and a flashlight so I could see the dial clearly and there were 3 adjustable pins on the dial along with temp indicators and words limit/ off fan/on /off. I set the bottom pin (fan off I think) to about 75 degrees, the middle pin (fan on to 110) and the limit off to about 170. I started the furnace and it seems to work ok. I watched and the dial would turn as the furnace heated up, when it got to about 100 -115 the blower would kick on, when the house thermostat got to its setting the gas would turn off and the blower continue to run until the furnace cooled to below 70 - 75. So I guess I fixed it but I don't know what the heck I'm doing. Does anyone know the correct settings for a Honeywell fan / limit control? This is a Sears 145000BTU input,forced draft furnace. I'm asking this OT questions here because there always seems to be a lot of good information about everything on this board. Thanks. Phil
Replies:
Home
| Forums
Today's Featured Article -
Third Brush Generators - by Chris Pratt. While I love straightening sheet metal, cleaning, and painting old tractors, I use every excuse to avoid working on the on the electrics. I find the whole process sheer mystery. I have picked up and attempted to read every auto and farm electrics book with no improvement in the situation. They all seem to start with a chapter entitled "Theory of Electricity". After a few paragraphs I usually close the book and go back to banging out dents. A good friend and I were recently discussing our tractor electrical systems when he stated "I figure it all comes back to applying Ohms Law". At this point
... [Read Article]
Latest Ad:
18-32 Case Cross Motor
[More Ads]
Copyright © 1997-2025 Yesterday's Tractor Co. All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Yesterday's Tractors - Antique Tractor HeadquartersWebsite Accessibility Policy |
|